Chapter 2: Installation
Chapter 2: Installation
This chapter provides information to install the CPP Monitor 2000.
Please read the entire chapter before starting.
OPERATING ENVIRONMENT
The CPP Monitor 2000 should be mounted and operated in a clean,
dry environment. The unit is microprocessor controlled and as a
result it should not be installed near devices that generate strong
electromagnetic fields. Such interference is typically generated by
power switching equipment such as relays or contactors. A poor
operating environment may result in unwanted system resets and/or
system lockup. The temperature range the unit can operate in is
32°F to 122°F (0°C to 50°C). If the unit needs to operate below
freezing, a strip heater should be installed nearby.
MOUNTING THE UNIT
When you receive the unit, carefully remove it from the box.
Mounting tabs with holes are provided on the left and right sides of
the enclosure (see figure below). Mount the unit in a position that
allows easy access to the input terminal block, battery compart-
ment, on/off switch and the programming port. Also, there must be
a power outlet and telephone jack close to the unit.
CAUTION:The CPP Monitor 2000 is a sensitive electronic device. Personnel and
work area should be grounded before coming into contact with this device. Do
not install the CPP Monitor 2000 near strong electrostatic, electromagnetic,
magnetic or radioactive fields.
mounting dimensions